What specialist testing can show
TI-5000JX bench. Check the resolver and tachometer paths independently with the correct fixture.
TI-3000JX motor run. Confirm the full motor order, power lead, phase reference and supported TI-3000JX setup.
Starting lead. TI-5913 for the documented 18-contact bayonet.
MTS / Custom Servo MPM Resolver and Tachometer Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| MPM resolver/tachometer | TI-5913 on the scoped 18-contact bayonet. Identify the resolver and tachometer independently. |
| MPM with Unico SSI | Separate serial configuration and cable family. Confirm the original type key. |
| MaxPlus MPM order | Use the archived motor data for shaft, frame and feedback code. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Position feedback | Passive resolver excitation and sine/cosine return. |
| Speed feedback | Separate tachometer path in the TI-5913 branch. Obtain its fitted rating. |
| Fixture | TI-5913, 18-contact bayonet. |
Interface and measuring method
The resolver reports angle under the specified excitation. The tachometer gives speed-related feedback on its own circuit. Test each path on its matched setup.
Mounting and fit
Document motor frame, rear assembly and original position before removal. Check plug and cable retention before disturbing the resolver or tachometer.
Wiring and connector scope
Use the motor-specific pin map for excitation, return pairs and tachometer leads. Compare connector orientation and fitted polarity against the drive diagram.
Internal motor and machine cables
Separate the production motor loom and extension from the TI-5913 tester lead. Record both connector ends and cable routes when the fault is intermittent.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
A resolver is passive. Check isolated winding continuity against the matching drawing. Use the specified AC excitation on the approved test fixture for a signal check.
| Symptom | What to verify |
|---|---|
| No angle but tachometer path is sound | Check excitation and return wiring. |
| Angle stable but speed fault | Check tachometer path and drive settings. |
| Both paths fail when moved | Inspect the bayonet and isolated cable. |
Angle of alignment and commissioning
Preserve resolver direction and phase reference as well as tachometer polarity. Use the approved motor and drive process before any powered check.
Motor and drive applications
MTS MaxPlus MPM, documented resolver/tacho branch
Read the motor code and separate resolver position, tachometer speed and machine cable faults.
Related SpareFaber guides
Drawings, pin maps and manuals
- Mitchell Test Cable Index by Manufacturer Support. Custom Servo and MTS MPM rows, TI-5913
- Parker archived MTS MaxPlus MPM motor catalogue. Supplementary reference for the stated model or setup.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.