What specialist testing can show
TI-5000JX bench. Use the EQN425 profile and preserve the fitted memory and turn-count information.
TI-3000JX motor run. Mitchell documents the Indramat MHD digital path and identifies EQN425 in the hardware list. Its selection text prints EQN435. Confirm the actual installed profile before a motor run.
Starting lead. Match the fitted Indramat connector and the manual’s cable drawing. Module TI-5104 in the verified Indramat setup.
Bosch Rexroth Indramat MHD with EQN 425 Indramat Digital Multiturn Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| MHD with EQN 425 | Mitchell lists EQN425 among MHD feedback variants. Check the fitted encoder label and complete motor order. |
| MHD feedback option P | Rexroth’s type code for digital servo feedback with integrated multiturn absolute encoder. Verify the actual internal model. |
| ECN 413 / other MHD feedback | Mitchell lists singleturn and other OEM digital versions. The EQN 425 guide applies to the named fitted device. |
| EQN435 in run menu text | The Mitchell run article prints this spelling in its selection list while its identification section names EQN425. Confirm the actual software selection and label. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Feedback | Indramat digital multiturn with motor information in the feedback memory. |
| Tester count | Mitchell groups this legacy selection with the 2,048 incremental counts per revolution group. Treat the tester display convention separately from drive system resolution. |
| Turn information | EQN 425 is among the documented multiturn selections and reports revolution data. |
| OEM configuration | MHD P is the integrated multiturn option in the Rexroth project planning manual. |
Interface and measuring method
The drive receives position and identification through the OEM digital path. Multi-turn position and motor memory are distinct checks. A correct position report can coexist with a rejected motor identity.
Mounting and fit
Use the Rexroth MHD frame outline and the installed feedback assembly drawing. Record the locating seat, shaft engagement, harness and original fasteners before rear-end work.
Wiring and connector scope
Confirm the actual motor signal connector and the matched Indramat test lead. Keep the TI-5104 setup and the machine feedback wiring separate. Use the exact plug view in the applicable manual.
Internal motor and machine cables
Select the drive cable and internal harness by the complete MHD and drive orders, connector layout and fitted encoder label. Read the original harness map before substitution.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Turn count jumps while within-turn angle is stable | Check the fitted EQN type, turn fields and correct selection. |
| Motor mismatch after encoder exchange | Compare the original memory and complete MHD nameplate against the new assembly. |
| Run setup rejects the digital feedback | Verify the physical connector, adapter and software selection. The published menu and identification spellings differ. |
Angle of alignment and commissioning
Preserve the incoming motor data and mechanical reference. Confirm the supported run selection, alignment and readback with the installed firmware before a specialist run or memory transfer.
Motor and drive applications
Indramat MHD with fitted EQN 425
Identify the multiturn MHD variant and capture original motor memory before considering replacement.
Related SpareFaber guides
Drawings, pin maps and manuals
- Indramat Motors. Identification, MHD EQN425 option and Indramat run setup
- Indramat Digital Motors, Serial Encoders and Resolvers. Supplementary reference for the stated model or setup.
- Bosch Rexroth MHD project planning manual. Feedback code P, outline drawings and motor signal connection information.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.