What specialist testing can show
TI-5000JX bench. Check the multiturn SEL34 with the compatible classic HIPERFACE setup.
TI-3000JX motor run. Verify motor order, drive, pole count and alignment before selecting any run profile.
Starting lead. Verify the SEL34 suffix and fitted direct connector before using a documented classic HIPERFACE lead. Module TI-5104 on a verified classic HIPERFACE setup with the matching connector.
SICK Stegmann SEL34 Capacitive HIPERFACE Multiturn Encoder technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| SEL34-HFB0K02 · 1053403 | Exact SICK part in the datasheet below. Tapered shaft, radial 8-contact connector. |
| SEK34 | Singleturn capacitive branch. Check the full code and the drive’s position mode. |
| AKM GD and GR | The Mitchell-linked Kollmorgen table names SEL34 in these feedback positions. Match the actual installed variant. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Position scale | 512 within-turn steps and 4,096 absolute turns for 1053403 in the SICK position data. |
| Analogue periods | 16 sine/cosine periods per turn on the 1053403 example. |
| Supply | 7–12 V DC, with 8 V DC recommended by SICK on the cited model. |
| Mechanical configuration | Tapered shaft and radial male 8-contact connector for 1053403. Use the exact dimensional drawing. |
Interface and measuring method
The capacitive sensor provides absolute information through the HIPERFACE parameter channel and analogue process signals on sine and cosine paths. Check both against the exact model’s profile.
Mounting and fit
Use the SICK taper and stator-coupling outline for 1053403. Verify the actual suffix before applying the shaft movement limits, seating and fastening instructions from that drawing.
Wiring and connector scope
The following is the plug-in face shown on the SICK 1053403 data sheet. Use the document drawing to orient the connector. The motor bulkhead may use a different pin arrangement.
| Contact or circuit | Documented scope |
|---|---|
| Pins 1 and 6 | Supply and GND. |
| Pins 2 and 3 | +SIN and REFSIN. |
| Pins 4 and 5 | +COS and REFCOS. |
| Pins 7 and 8 | Data+ and Data−. |
Internal motor and machine cables
Use the motor order and both plug views to identify the internal loom. Match the shield termination and verify the drive cable separately. Confirm the approved direct tester lead for the fitted SEL34 connector.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Serial reads but process signal is poor | Verify the paired references, screen and exact supply. Inspect taper fit and the stator coupling. |
| Turns are absent after exchange | Read SEL versus SEK on the fitted label and verify the drive’s configured position mode. |
| Intermittent alarms near the motor | Inspect the eight-contact plug, latch and internal loom strain relief. |
Angle of alignment and commissioning
Preserve the original motor data and reference before removing the taper-mounted assembly. Verify the fitted feedback model, direction, turn mode and motor-specific alignment under the OEM procedure.
Motor and drive applications
Named in Kollmorgen AKM GD/GR and Festo feedback options
Compare the actual SEL34 shaft, coupling and multiturn output with the singleturn SEK34.
Related SpareFaber guides
Drawings, pin maps and manuals
- Kollmorgen AKM support. Linked AKM Feedback Description, GD and GR SEL34 rows
- SICK SEK34/SEL34 product information. Manufacturer reference for the indicated motor or feedback option. Check the fitted revision.
- SICK SEL34-HFB0K02 data sheet. Item 1053403 supply, shaft outline, position data and plug-in face pin table.
- Mitchell-linked AKM order key. Documented SEL34 feedback positions GD and GR.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.