What specialist testing can show
TI-5000JX bench. Confirm ID B and check the incremental serial and applicable commutation behavior.
TI-3000JX motor run. Verify the fitted motor order and available run selection.
Starting lead. Select the Mitchell lead from the matching Sigma-II motor connector row.
Yaskawa UTSSH-B16 16-Bit Incremental Serial Encoder technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| UTSSH-B16 | 16-bit incremental serial, ID B. Confirm the fitted Sigma-II motor and plug. |
| UTSIH-B16 | Also listed under ID B. A shared serial profile alone leaves shaft, harness and mechanical fit to verify. |
| UTTIH-B17 | 17-bit incremental serial, ID C. Compare the extra bit and actual motor generation before choosing a profile. |
| UTSAH-B16 | 16-bit absolute, ID 1. Retention and controller requirements differ from ID B. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| ID B resolution | 16 bits, 65,536 positions per revolution. |
| ID C comparison | 17 bits, 131,072 positions per revolution on the documented UTTIH-B17 profile. |
| Motor scope | Mitchell places UTSSH-B16 in Sigma-II and lists separate cable options by motor connection. |
| Device interface | Incremental information is conveyed in serial messages. Confirm the exact supply and pin view by fitted motor and encoder order. |
Interface and measuring method
The drive reads changing serial position and uses the expected encoder ID to interpret it. A responding encoder can still give the wrong travel if the selected profile or drive count differs. Check the reported ID and the count change over a known turn.
Mounting and fit
Compare the fitted encoder label, shaft arrangement, mounting seat and rear-cover clearance with the matched motor drawing. Record the incoming reference and cable route. A shared B16 suffix does not establish the same mechanical assembly.
Wiring and connector scope
Use the Sigma-II connector map for the complete motor order. Mitchell lists TI-5764, TI-5765, TI-5762 and TI-5766 under Sigma-II feedback cables. Choose the actual fixture by the contact view and documented connection.
Internal motor and machine cables
Record the plug at the encoder, motor bulkhead and SERVOPACK. Identify the OEM machine cable and internal loom from the actual orders. Treat the named Mitchell leads as diagnostic fixtures.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Replacement responds at the wrong count | Compare the ID B 16-bit and ID C 17-bit profiles, then check the full suffix. |
| Similar B16 encoder changes reference behavior | Confirm incremental ID B or absolute ID 1 and match the drive configuration. |
| Dropouts start at one cable position | Inspect the motor plug and cable flex point before removing the encoder. |
Angle of alignment and commissioning
Record the motor reference, direction and drive configuration before removal. After fitting, verify ID B, repeatable count and reference recovery through the applicable Yaskawa procedure.
Motor and drive applications
Yaskawa Sigma-II
Read the UTSSH suffix and distinguish the ID B incremental profile from 16-bit ABS.
Related SpareFaber guides
Drawings, pin maps and manuals
- Yaskawa Serial Encoder Identification. Encoder ID table B row, UTSSH-B16 and UTSIH-B16
- Yaskawa Serial Encoder Testing. Supplementary reference for the stated model or setup.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.