What specialist testing can show
TI-5000JX bench. Mitchell names the AR62/AR63 SSI option. Match the exact SSI order, 10–30 V arrangement where applicable, clock/data wiring and compatible bench fixture. A dedicated AR62 lead remains to be verified.
TI-3000JX motor run. The documented scope is encoder and connection diagnosis. Motor-run setup requires the fitted application and drive details.
Starting lead. Match the SSI order code and cable drawing. No model-specific Mitchell lead established.
Hengstler AR62 SSI Heavy-Duty SSI Absolute Encoder technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| AR62 with SG | Aluminium-housing variant with SSI Gray in the published order table. Record the complete order. |
| AR62 with SB | SSI binary variant in the same housing family. Match the receiver format to the label. |
| AR63 and AR62 OL | AR63 is the stainless family. OL identifies CANopen in the catalogue. Use the interface-specific drawing for each. |
Production and end-of-life status
Hengstler provides a family product record. Confirm availability and any replacement using the complete AR62 order.
Specifications
| Parameter | Verified scope |
|---|---|
| Published SSI order example fields | 0012 is 12-bit singleturn and E is 10–30 V DC in the documented SSI order table. |
| Flange and shaft | L.72 is a synchro-clamping flange with a 10 mm shaft and IP67 designation. Q.76 is a square flange with a 9.52 mm shaft and IP67 designation. Match the full code. |
| Radial connector | Code 8 is the 8-contact M12 branch. B and F are cable options. |
| SSI interpretation | SG Gray or SB binary. Preset and direction circuits are provided in the published pin table. |
Interface and measuring method
The controller clocks a position word out of the encoder. With an incorrect data format the word can be electrically valid and still give a jumping or scaled position. Check bit format and the preset or direction input state along with the wiring.
Mounting and fit
Use the flange and shaft fields before selecting a coupling. Compare the installed seat, shaft diameter, axial clearance and gasket or mating plug requirements with the appropriate outline in the data sheet.
Wiring and connector scope
For the code-8 M12 SSI version use the manufacturer’s connector view. Pin 1 is supply and pin 2 is return. Pins 4/6 form the clock pair and 5/8 form the data pair. Read polarity markings in the drawing. Pin 3 is preset and 7 is direction. Follow the published shield scheme.
| Contact or circuit | Documented scope |
|---|---|
| M12 1 / 2 | Supply and 0 V on the scoped SSI connector. |
| M12 4 / 6 and 5 / 8 | Clock pair and data pair respectively. Match the true and complement markings on the manufacturer drawing. |
| M12 3 / 7 | Preset and direction inputs. Check their intended state in the controller documentation. |
Internal motor and machine cables
Use an exact SSI cable or correctly mapped approved extension. Keep clock and data as pairs, verify shell and screen termination and compare both connector drawings. The CANopen version uses its own cable map.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Position jumps with smooth shaft travel | Check SG/SB decoding, word length and wiring integrity. |
| Word is frozen or intermittently absent | Verify the clock and data pairs, supply and connector condition at the approved breakout. |
| Position is smooth but reversed or offset | Review the direction input, preset state and mechanical coupling reference. |
Angle of alignment and commissioning
Record the machine reference and direction before removal. Verify the new position at the reference and over an independent mechanical movement. Apply any preset only through the OEM machine procedure.
Motor and drive applications
Industrial machine axis, AR62 SSI order
Use the complete order code to separate SSI wiring and word format from the other AR62 interfaces.
Related SpareFaber guides
Drawings, pin maps and manuals
- Hengstler Encoders. Absolute Encoders, AR62 / AR63 with SSI, CANopen and analogue options
- Unico SSI Serial Encoders. Supplementary reference for the stated model or setup.
- Hengstler AR62/AR63 technical data. SSI order code, mounting dimensions and the separate 8-contact SSI connector table.
- Hengstler AR62/AR63 product family. Current family configuration reference.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.