What specialist testing can show
TI-5000JX bench. Use the EKS36 singleturn DSL profile after confirming the GE motor option and fitted suffix.
TI-3000JX motor run. Verify the exact AKM motor configuration and supported EKS36 run setup.
Starting lead. Verify the AKM hybrid connector and approved EKS36 test fixture.
Kollmorgen AKM GE / SICK EKS36 Singleturn HIPERFACE DSL Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| AKM GE | The linked feedback code table names EKS36 for this singleturn optical DSL option. |
| EKS36-0JF0A018A · 1052016 | Verified standalone SICK reference for the electrical and connector example below. Check the actual AKM-fitted suffix. |
| EKM36 | Multiturn DSL family. Verify the motor option and data requirements before comparing replacements. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Position | 18-bit singleturn for the SICK 1052016 example, with 262,144 steps per revolution. |
| Supply | 7–12 V DC for the SICK 1052016 example. Use the approved interface circuit. |
| PCB connector | Four positions. SICK lists JST GHR-04V-S as the recommended mate for the stated example. |
| Signal path | HIPERFACE DSL uses a shared power and data pair at the stated encoder connection. |
Interface and measuring method
The receiver and encoder exchange digital position and status over the DSL link. A DC supply measurement can help check power. A compatible DSL receiver is needed to assess data quality.
Mounting and fit
Use the AKM frame drawing for the fitted housing and cable route. Use the SICK dimensional drawing for the actual suffix. Capture the seating and stator coupling arrangement before opening the feedback end.
Wiring and connector scope
The table applies to the 1052016 encoder connector view in the SICK data sheet. The AKM hybrid plug uses its own OEM map. Verify the fitted suffix before using the pin numbers.
| Contact or circuit | Documented scope |
|---|---|
| Pins 2 and 3 | Pin 2 +US/DSL+, pin 3 GND/DSL− on SICK 1052016. |
| Pins 1 and 4 | Unused on the cited example. |
Internal motor and machine cables
Choose the AKM motor-to-drive hybrid assembly by motor frame, order and drive. For an internal loom, confirm the actual EKS36 connector and revision. Use the approved cable and screen arrangement.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Hybrid motor alarms and encoder reads directly | Inspect the bulkhead, cable and drive receiver using the AKM hybrid drawing. |
| Supply present and DSL fails | Check the fitted pair, compatible software/profile and the data link with an approved fixture. |
| Position scale changes after replacement | Check GE, the actual EKS36 suffix and singleturn data requirements. |
Angle of alignment and commissioning
Save the original motor data and incoming alignment reference before replacement. Verify the fitted position mode and exact Kollmorgen commissioning process with an approved DSL fixture.
Motor and drive applications
Kollmorgen AKM GE
Decode GE and choose the right singleturn DSL profile, connector and replacement memory procedure.
Related SpareFaber guides
Drawings, pin maps and manuals
- Kollmorgen AKM support. Linked AKM Feedback Description table, GE row and DSL EKS/EKM 18-bit profile
- SICK EKS36-0JF0A018A data sheet. Example 1052016 dimensions, 18-bit DSL data, rated supply and PCB pin view.
- Kollmorgen AKM connectivity manual. Motor frame and connector identification. Confirm the fitted code and drive.
- Mitchell-linked AKM feedback code table. GE and other feedback options by motor code.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.