Identify the fitted part
| Guide scope | MTS / Custom Servo MPM / Unico 319-663 SSI — Motor application |
|---|---|
| Feedback identity | Unico 319-663 |
| Manufacturer MPN / full suffix | MPM / Unico 319-663 SSI is the scoped family/designation. Match every additional character on the fitted label before ordering. |
| OEM service ID / motor order | Not established for a specific fitted unit. Record the full motor label, feedback option and any OEM service ID separately. |
| Interface | SSI absolute |
| Documented starting connection | TI-5636 drawing, reversed 12-contact M23 orientation. Mitchell says a ready cable is not currently offered; verify connector view and 10–30 V external supply. |
| Material distinction | TCG362 is MPM resolver/tach; TCG388 is incremental. TCG119 is the standalone Unico device. |
Specialist testing: connection before conclusion
| TI-5000JX bench scope | Conditional bench scope: Identify MPM’s Unico SSI option and verify code format and clock/data connections. Exact fixture, supply and drawing must agree before connection. |
|---|---|
| Starting lead / fixture | TI-5636 drawing, reversed 12-contact M23 orientation. Mitchell says a ready cable is not currently offered; verify connector view and 10–30 V external supply. |
| Profile / module | Match exact profile, supply, connector and installed software. A named cable is not a complete test procedure. |
| TI-3000JX motor-run scope | Bench serial count/data scope. Mitchell supplies no Unico motor direction or alignment data; exact MPM motor-run setup remains open. |
The admission evidence is Mitchell Test Cable Index by Manufacturer Support — PDF pages 4,9,15, TI-5636. Verify installed tester software, the actual sensor option and the fixture before connection. A bench result describes the tested configuration; it does not by itself clear the complete drive, brake, machine cable or loaded axis.
Production and replacement status
Current production status, exact-order stock and an approved successor have not been confirmed in the cited evidence. Retain the installed label and ask for an exact-order check before selecting a replacement.
Specifications and interface
| SSI word | 12 position bits + 12 revolution bits in a 24-bit Gray word, followed by an alarm bit. |
|---|---|
| Supply and signaling | 10–30 V external encoder supply; 5 V serial signal levels. Use the original diagram for the shared 0 V reference. |
| Counts and retention | 4,096 positions per revolution and 4,096 revolutions; the documented device does not use battery backup. |
| Supply / output compatibility | Use the complete fitted label and its wiring drawing. No universal supply, receiver level or excitation is assigned to this family guide. |
| Exact dimensions, torque and pins | Use the scoped drawing or request it through the enquiry. Values from another suffix, connector view or motor revision are not substituted. |
SSI shifts a clocked absolute data word. This Unico example uses a 24-bit Gray word comprising 12 position bits and 12 revolution bits, followed by an alarm bit. Power supply and serial signal levels are different: the cited external supply is 10–30 V while data/clock use 5 V levels. Follow the original diagram and common-reference arrangement.
Mechanical fit and retention
Photograph the incoming shaft/coupling position, locating seat, restraint, fasteners and cable exit before removal. Check accessible looseness, contamination, bearing roughness and signs of rubbing after isolation. Identify whether the assembly has its own bearings, a hollow-shaft clamp or a motor-retained sensor; the exact drawing controls that decision. Do not lever against a sensing disc or apply a torque from a similar-looking model.
MPM is named in the cable index with Unico SSI and TI-5636. Mitchell’s Unico article describes a reversed-orientation 12-contact connection and says a ready cable is not currently offered. Its 10–30 V encoder supply is external; the serial signals remain 5 V levels. No Unico motor direction/alignment data are provided.
Wiring and connector boundaries
Map five boundaries separately: the sensor plug or PCB, internal motor loom, motor bulkhead, external machine cable and drive/tester end. Record connector gender, keying, contact numbering and whether the drawing shows mating or termination side. The documented Mitchell lead is a starting fixture, not a pin map for a handmade adapter. Keep power, temperature, brake, shield and feedback contacts identified individually.
Starting connection for this guide: TI-5636 drawing, reversed 12-contact M23 orientation. Mitchell says a ready cable is not currently offered; verify connector view and 10–30 V external supply.. Use the source below for its named scope. Any unverified pin assignment remains open until the correct drawing is available.
Internal loom and machine cables
TI-5636 identifies the documented test connection, not an OEM internal loom. Mitchell describes reversed contact orientation compared with the similar Indramat-style connector and says a ready cable is not currently offered. Obtain the MPM internal assembly and external machine-cable drawings before sourcing a loom or building a matched fixture.
Practical fault checks
Isolation and measurement conditions
Secure moving loads, isolate and lock out the relevant energy sources, follow the specified discharge time and have a qualified technician verify isolation before physical inspection or resistance checks. Disconnect both cable ends before continuity/short testing. Powered supply measurements, rotation, retention work and alignment require the approved fixture and procedure.
| Configuration-specific check | MPM is named in the cable index with Unico SSI and TI-5636. Mitchell’s Unico article describes a reversed-orientation 12-contact connection and says a ready cable is not currently offered. Its 10–30 V encoder supply is external; the serial signals remain 5 V levels. No Unico motor direction/alignment data are provided. |
|---|---|
| Fault appears when the machine cable moves | With the system isolated and both ends disconnected, inspect flex points, connector engagement and repaired sections. Check end-to-end continuity and unintended shorts against the actual pin map, accounting for intentional shield bonds. |
| No feedback or intermittent loss at the drive | After label and fixture verification, have a qualified technician check the specified supply or excitation through an approved breakout. Compare at the source and load under the OEM procedure; never assume a voltage from the connector shell. |
| Position reads but status or retained reference is wrong | Save detected identity, status and incoming position. Check the documented profile and retention arrangement before a reset, battery intervention or data transfer. |
Alignment, reference and memory
Preserve machine zero, direction and the incoming SSI position before removal. Mitchell explicitly states that it has no Unico motor alignment or forward armature information. A serial count pass cannot supply the missing MPM phase relationship or a complete motor-run procedure.
Motor and drive applications
MPM / Unico 319-663 SSI. TCG362 is MPM resolver/tach; TCG388 is incremental. TCG119 is the standalone Unico device.
A matching maker, connector shell or protocol name is not a complete compatibility chain. Keep motor order → feedback option → internal loom → bulkhead → machine cable → drive configuration recorded separately. No unverified alternate part is offered by this guide.
Drawings, manuals and evidence
- Mitchell Test Cable Index by Manufacturer Support — PDF pages 4,9,15, TI-5636
- Unico SSI Serial Encoders — Named model, option or connection; see the proposal locator. Bench evidence and motor-run scope remain separate.
Exact OEM technical PDF remains to obtain. The Mitchell reference establishes only the documented device or motor/feedback connection; it does not fill missing ratings or pins.
Common questions
What should accompany a MPM / Unico 319-663 SSI enquiry?
Send clear photographs of the motor and feedback labels, every suffix/ID, both connector faces, drive model, exact alarm and the circumstances of the fault. Include recent wiring, bearing, encoder or parameter work.
Can the listed Mitchell lead be used as a replacement machine cable?
The lead is documented for the stated test connection. OEM internal looms and machine extensions require their own part numbers, pin maps and mechanical ratings.
Does a successful feedback bench test prove that the motor can be run?
Bench serial count/data scope. Mitchell supplies no Unico motor direction or alignment data; exact MPM motor-run setup remains open. A complete run assessment also checks motor power, brake, protection and mechanical conditions.
When does a site visit or send-in evaluation make sense?
A site visit can help when the fault depends on the drive, installation or moving cable. Send-in evaluation can isolate a removable feedback assembly or supported motor configuration. Agree scope, packing, availability and turnaround with SpareFaber after identification.
Request a scoped service evaluation