Encoder and resolver technical library

Control Techniques Unimotor hd 190UDD / 190EDD Heidenhain EnDat FB / EB Singleturn / Multiturn Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment

Control Techniques Unimotor hd 190UDD / 190EDD | Heidenhain EnDat FB / EB | ST + MT | Installation, Repair, Alignment workshop illustration

Control Techniques Unimotor hd 190UDD / 190EDD · Heidenhain EnDat FB / EB

SpareFaber offers UAE site visits and send-in evaluation for the Control Techniques Unimotor hd 190UDD / 190EDD. Use this guide to identify the fitted feedback, prepare the right cable and drawing, and investigate faults before ordering parts or starting alignment.

Request a UAE site visit or bench evaluation

Find your part number

Compare the motor nameplate, complete part number and fitted feedback label. FB is optical ECN 1313 single-turn. EB is optical EQN 1325 multiturn. Compare actual EnDat revision, analogue track, serial turn range and installed cable.

What to identify Catalogue reference
Physical stack 190 mm, length D
230 V example 190EDD…
460 V example 190UDD…
Feedback order FB single-turn ECN 1313 / EB multiturn EQN 1325

Include any special suffixes and clear photos of the mating connectors and the feedback mount.

What specialist testing can establish

Check the fitted ECN 1313 or EQN 1325 suffix and compatible EnDat setup. Read identity and position, then compare analogue signal periods with the exact OEM signal configuration.

SpareFaber can assess a site visit or a send-in evaluation. Direct encoder checks and complete motor run tests require confirmed hardware and independent setup decisions.

Reference specifications

Parameter Catalogue value Scope
Continuous stall torque 62 N·m 190 mm Unimotor hd data for the proposed stack
Voltage variants ED 230 V and UD 460 V Identify winding and matching drive separately
Position feedback FB optical single-turn / EB optical multiturn Use the actual EnDat and catalogue cable, and verify the analogue path

Mechanical fit

Use the Unimotor hd 190 mm outline for the D stack. Record flange, shaft/key, brake clearance and connector arrangement from the complete order. Review voltage/winding type independently of mechanical fit.

Check the fitted part’s complete drawing before choosing a substitute. Compare shaft or bore, mounting dimensions, locating features and harness clearance.

Wiring and connector scope

Use the matching FB / EB OEM drawing for clock/data, supply, sense where specified, and analogue pairs. Confirm the exact connector or cable from the full order.

Identify the connector face and drawing revision. Approved service personnel should isolate power, secure the load and verify the relevant wiring before any powered checks.

Internal wiring and machine cables

Read the Unimotor hd 190 connector selection against the fitted supply, brake and encoder choices. Compare the two ends of both power and feedback cables with the drive and motor drawing.

Send clear photos of both mating connectors and the cable label. Note where the harness flexes and whether a connector, cable or drive was recently replaced.

Fault checks

Observed symptom What to check
Motor type selected but feedback is missing Check 190ED/190UD wiring, the FB/EB or AE field, and the installed input.
Alignment fault after repair Verify rotation, mechanical seating and the original commutation reference.
Fit is correct but the drive reports a mismatch Compare winding, feedback revision and drive profile to the full motor code.

Alignment and commissioning

Capture the incoming signal reference and exact motor/encoder assembly. Compare the retained or measured angle with the specified Unimotor hd setup and matched drive procedure after installation.

Compare readable identification, position and turn scope to the exact feedback information, then verify the axis reference on the matching system.

Production and availability

Request availability against the complete Unimotor hd 190UDD / 190EDD order, serial number and feedback label. SpareFaber offers installation, fault diagnosis and alignment assessment. Ask separately for part supply or replacement options.

Motor and drive applications

Control Techniques Unimotor hd application with the exact amplifier, voltage and feedback input supporting the fitted order.

Send the motor order, drive nameplate, feedback label and fault history to check the service scope and assembly revision.

Drawings and manuals

Common questions

What should I send for an evaluation?

Send the complete Unimotor hd 190UDD / 190EDD order, feedback label, connectors at both ends, drive order and the original fault or alarm.

Can I match the feedback from the motor frame?

Use the order information above, then compare the actual feedback label, signals, drawings and reference procedure.

Can you check the motor at our site?

Request a UAE site visit or bench evaluation. Share the location, equipment labels and what happened before the fault so the service team can confirm the appropriate scope.

Request service

Send the full motor and encoder IDs, drive model, connector pictures and fault history with your service enquiry. Include your location for an on-site visit.

Enquire about this encoder or resolver

Tell us what needs checking. We’ll review the details and confirm the scope and quotation before booking chargeable work.

What do you need help with?