Schneider Electric BMH1904P Classic HIPERFACE 128 periods Singleturn / Multiturn Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment

Schneider Electric BMH1904P | Classic HIPERFACE 128 periods | ST + MT | Installation, Repair, Alignment workshop illustration

Schneider Electric BMH1904P · Classic HIPERFACE 128 periods

SpareFaber offers UAE site visits and send-in evaluation for the Schneider Electric BMH1904P. Use this guide to identify the fitted feedback, prepare the right cable and drawing, and investigate faults before ordering parts or starting alignment.

Request a UAE site visit or bench evaluation

Find your part number

Compare the motor nameplate, complete part number and fitted feedback label. 190 mm flange. Stall reference with LXM32•MC10N4. Optical feedback code 1 single-turn or 2 multiturn. Verify full suffix, mechanical drawing, brake and connector style.

What to identify Catalogue reference
Motor base BMH1904P
Flange 190 × 190 mm catalogue flange
Optical encoder code 1 Single-turn, 128 sine/cosine periods
Optical encoder code 2 Multiturn, 128 sine/cosine periods and 4,096 turns

Include any special suffixes and clear photos of the mating connectors and the feedback mount.

What specialist testing can establish

Read the fitted HIPERFACE identity and position on a supported setup and check the analogue tracks separately. Compare feedback data at motor and drive boundaries and preserve the original motor-specific data for service.

SpareFaber can assess a site visit or a send-in evaluation. Direct encoder checks and complete motor run tests require confirmed hardware and independent setup decisions.

Reference specifications

Parameter Catalogue value Scope
Torque reference 100 N·m Catalogue stall combination with LXM32•MC10N4. Confirm the drive and cooling conditions on site.
Single-turn / multiturn Both optical codes in one guide Confirm complete fitted code and label. Smaller analogue-period options have their own order details.
Catalogue position resolution 131,072 points/revolution with the stated Lexium 32 combination Keep drive interpolation, analogue periods and raw device resolution distinct
Example BMH order pair BMH1904P31A2A and BMH1904P32A2A These examples distinguish encoder code 1 versus 2 within the reviewed build

Mechanical fit

Use the BMH1904P drawing for flange/pilot, shaft end, connector type and brake-length dimensions. Match the fan option where fitted and keep its envelope and service needs in the order check.

Check the fitted part’s complete drawing before choosing a substitute. Compare shaft or bore, mounting dimensions, locating features and harness clearance.

Wiring and connector scope

Use the Lexium 32 BMH motor feedback connection for the exact assembled motor. Check serial data, supply and analogue paths using the specified contact-side drawing. Keep power, brake and thermal leads identified independently.

Identify the connector face and drawing revision. Approved service personnel should isolate power, secure the load and verify the relevant wiring before any powered checks.

Internal wiring and machine cables

Match the Schneider BMH encoder cordset and amplifier at both ends. Check mounting style, retention, connector contact view, length and flex rating. Use the full order table for the motor power cordset.

Send clear photos of both mating connectors and the cable label. Note where the harness flexes and whether a connector, cable or drive was recently replaced.

Fault checks

Observed symptom What to check
Drive rejects replacement feedback Match the optical 1/2 order and readable identity to the actual motor.
Serial position reads but movement looks noisy Check the 128-period analogue tracks and screen together with the cable.
Multiturn position changed after work Verify the turn configuration and the machine reference on the matched drive.

Alignment and commissioning

Record the installed drive reference, fitted encoder label and readable motor information before disturbing the holder. Verify direction and commutation under the appropriate Lexium commissioning procedure.

Compare readable identification, position and turn scope to the exact feedback information, then verify the axis reference on the matching system.

Production and availability

Request availability against the complete BMH1904P order, serial number and feedback label. SpareFaber offers installation, fault diagnosis and alignment assessment. Ask separately for part supply or replacement options.

Motor and drive applications

Lexium 32 LXM32•MC10N4 is the reference for this proposal. Confirm drive size against the complete motor and application.

Send the motor order, drive nameplate, feedback label and fault history to check the service scope and assembly revision.

Drawings and manuals

Common questions

What should I send for an evaluation?

Send the complete BMH1904P order, feedback label, connectors at both ends, drive order and the original fault or alarm.

Can I match the feedback from the motor frame?

Use the order information above, then compare the actual feedback label, signals, drawings and reference procedure.

Can you check the motor at our site?

Request a UAE site visit or bench evaluation. Share the location, equipment labels and what happened before the fault so the service team can confirm the appropriate scope.

Request service

Send the full motor and encoder IDs, drive model, connector pictures and fault history with your service enquiry. Include your location for an on-site visit.

Enquire about this encoder or resolver

Tell us what needs checking. We’ll review the details and confirm the scope and quotation before booking chargeable work.

What do you need help with?