Encoder and resolver technical library
Siemens 1FK7100-3 G2 High Inertia Heidenhain EnDat 2.1 E Multiturn Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment
Siemens 1FK7100-3 G2 High Inertia · Heidenhain EnDat 2.1 E
SpareFaber offers UAE site visits and send-in evaluation for the Siemens 1FK7100-3 G2 High Inertia. Use this guide to identify the fitted feedback, prepare the right cable and drawing, and investigate faults before ordering parts or starting alignment.
Request a UAE site visit or bench evaluation
Find your part number
Compare the motor nameplate, complete part number and fitted feedback label. SH100, BC71. E = AM2048S/R multiturn. M0 at 100 K. Catalogue row without DRIVE-CLiQ. Identify full motor and fitted encoder ID.
| What to identify | Catalogue reference |
|---|---|
| High Inertia base | 1FK7100-3 |
| Physical size | Shaft height 100, High Inertia |
| Order example group | BC71 |
| Feedback code | E, AM2048S/R |
Include any special suffixes and clear photos of the mating connectors and the feedback mount.
What specialist testing can establish
Confirm E-code, fitted AM2048S/R label and EnDat 2.1 mode. Check identity, serial position and the analogue path separately with a supported setup.
SpareFaber can assess a site visit or a send-in evaluation. Direct encoder checks and complete motor run tests require confirmed hardware and independent setup decisions.
Reference specifications
| Parameter | Catalogue value | Scope |
|---|---|---|
| Stall torque | 18 N·m at 100 K | High Inertia 510–720 V table with exact winding and actual operating conditions |
| Position track | EnDat 2.1 with 2,048 analogue periods | Read fitted motor/encoder order and any serial/analogue supported variant |
| Mechanical turns | Multiturn model, 4,096 turns at the referenced type | Confirm fitted device ID and drive processing |
Mechanical fit
Match the 1FK7100-3 High Inertia outline and brake option, exact shaft assembly and motor-encoder interface. Compare actual label, flange and rear mount when selecting a replacement.
Check the fitted part’s complete drawing before choosing a substitute. Compare shaft or bore, mounting dimensions, locating features and harness clearance.
Wiring and connector scope
Identify the E-code signal chain and correct EnDat clock/data plus analogue pairs. Match fitted supply, sense and connector contact view to the motor and drive documentation.
Identify the connector face and drawing revision. Approved service personnel should isolate power, secure the load and verify the relevant wiring before any powered checks.
Internal wiring and machine cables
Use the High Inertia and SINAMICS reference for the complete non-DRIVE-CLiQ feedback build. Match the drive or applicable sensor interface module and exact Siemens cable code.
Send clear photos of both mating connectors and the cable label. Note where the harness flexes and whether a connector, cable or drive was recently replaced.
Fault checks
| Observed symptom | What to check |
|---|---|
| Feedback fails after a drive or cable change | Check the exact feedback code, sensor interface module and connection type. |
| Absolute position or reference disagrees | Check retained turn range, stored reference and motor/encoder identity. |
| Holding brake or shaft parts differ | Use the exact High Inertia part drawing for fit and clearance. |
Alignment and commissioning
Capture the incoming motor/encoder code, original mechanical position and reference condition. Follow the actual Siemens reference procedure for the option, including machine homing or commutation verification.
Compare readable identification, position and turn scope to the exact feedback information, then verify the axis reference on the matching system.
Production and availability
Request availability against the complete 1FK7100-3 G2 High Inertia order, serial number and feedback label. SpareFaber offers installation, fault diagnosis and alignment assessment. Ask separately for part supply or replacement options.
Motor and drive applications
Siemens SINAMICS combination appropriate to the model and non-DRIVE-CLiQ feedback order, confirmed from the installed hardware.
Send the motor order, drive nameplate, feedback label and fault history to check the service scope and assembly revision.
Drawings and manuals
- Siemens SIMOTICS S-1FK7 High Inertia configuration manual extension. High Inertia 510–720 V data and options table, order patterns and torque curves.
Common questions
What should I send for an evaluation?
Send the complete 1FK7100-3 G2 High Inertia order, feedback label, connectors at both ends, drive order and the original fault or alarm.
Can I match the feedback from the motor frame?
Use the order information above, then compare the actual feedback label, signals, drawings and reference procedure.
Can you check the motor at our site?
Request a UAE site visit or bench evaluation. Share the location, equipment labels and what happened before the fault so the service team can confirm the appropriate scope.
Request service
Send the full motor and encoder IDs, drive model, connector pictures and fault history with your service enquiry. Include your location for an on-site visit.
Enquire about this encoder or resolver
Tell us what needs checking. We’ll review the details and confirm the scope and quotation before booking chargeable work.